IAI America ISWA User Manual

Page 68

Advertising
background image

60

1

1. Procedure for Motor Replacement

  6HOHFWWKHVSHFL¿FD[LVSDUDPHWHUWDE

  2SHQWKHVSHFL¿FD[LVSDUDPHWHUDQGVHOHFW1R+RPH3UHVHW9DOXH

  &KDQJHWKHVHWWLQJRIVSHFL¿FD[LVSDUDPHWHU1R KRPHSUHVHWYDOXH 

Add or subtract the value measured in (12) to/from the value currently input.

*The setting unit is 0.001mm.

Example: When subtracting 1mm

Home preset value = Current setting value -1000

(7) Write the new data.

Select specific axis parameter tab

Select No. 12 "Home Preset Value"

Press the transfer to controller button to write data in the controller.

(3) Select a parameter.

Press this button to open the parameter edit window.