3.
Operation

[9] 3-Point Movement (For Single Solenoid System) ••• PIO Pattern 3

With the combination of ST0 and ST1, the actuator is moved to the target position.

Refer to the table below for

the combination of movement

signals.

*Positioning Band

(Parameter No. 1)

Passing

the Intermediate

Position

Passing

the Intermediate

Position

Forward

Position

Backward

Position

Intermediate

Position

*

*

*

Backward Position Movement Signal (ST0)

Forward Position Movement Signal (ST1)

Intermediate Position Movement Signal (ST2)

(PIO Pattern 4 only)

Backward Position Detection Output (LS0)

Forward Position Detection Output (LS1)

Intermediate Position Detection Output (LS2)

Backward Positioning Completion Output (PE0)

Forward Positioning Completion Output (PE1)

Intermediate Positioning Completion Output (PE2)

Actuator Operation

Following table shows the combination of the movement signals by each PIO pattern and the

destination determined by it.

PIO Pattern 3

Input

Signal

Forward Position

Movement

Backward Position

Movement

Intermediate Position

Movement

ST0

OFF

ON

Both being on or both off

(selected in the initial setting)

ST1

ON

OFF

PIO Pattern 4

Input

Signal

Forward Position

Movement

Backward Position

Movement

Intermediate Position

Movement

ST0

OFF

ON

OFF

ST1

ON

OFF

OFF

ST2

OFF

OFF

ON