Z pio pattern 1 [teaching type, 37 4. w iring – IAI America PCON-CF User Manual

Page 55

Advertising
background image

37

4. W

iring

z PIO pattern 1 [Teaching Type]

0 [V]

0 [V]

+24 [V]

+24 [V]

PIO

Brown 1

Red 1

Orange 1

Yellow 1

Green 1

Blue 1

Purple 1

Gray 1

White 1

Black 1

Brown 2

Red 2

Orange 2

Yellow 2

Green 2

Blue 2

Purple 2

Gray 2

White 2

Black 2

Brown 3

Red 3

Orange 3

Yellow 3

Green 3

Blue 3

Purple 3

Gray 3

White 3

Black 3

Brown 4

Red 4

Orange 4

Yellow 4

Green 4

Blue 4

Purple 4

Gray 4

White 4

Black 4

Controller end

(signal abbreviation)

Output s

ide

Command position 1

Command position 2

Command position 4

Command position 8

Command position 16

Command position 32

Operation mode

Manual operation

switching

Jog+

Jog-

Operating mode

Home return

Pause

Start/current-
position write

Alarm reset

Servo ON

Completed position 1

Completed position 2

Completed position 4

Completed position 8

Completed position 16

Completed position 32

Moving

Current operation mode

Position zone output

Operating mode status

Home return completion

Position complete/write

completion

Ready

Emergency stop

Alarm

Input si

de

Upper
stage

Lower
stage

Host system <PLC> end

(Note) *STP, *ALM and *EMGS are based on the negative logic.

Advertising