⑦ Encoder multi-rotation data reset (2)
Press the F1 (OK) key.
⑧ Home preset value auto refresh
Press the PAGE UP key and do not press the F1
(OK) key.
▪ Do not execute the item of “home preset value auto refresh.” (Be careful especially when
performing an absolute reset without a jig.)
▪ If “home preset value auto refresh” is executed without using an adjusting jig, the home position
becomes misaligned.
▪ If “home preset value auto refresh” is executed by mistake, perform an absolute reset work
again using an adjusting jig. (Up to the work steps of ⑧ above)
⑨
Remove the adjusting jig. Remove an
emergency stop reset adjusting jig if it is set.
After resetting the EMERGENCY STOP button,
press the F1 (OK) key.