Models KBAC-24D, 27D: Designed to accept

single-phase AC line input only (Terminals “L1”,

“L2”). Rated for 208/230 Volt AC line input with

Jumper J1 set to the “230V” position (factory

setting). Rated for 115 Volt AC line input with

Jumper J1 set to the “115V” position. See Figure 7

on page 14.

Model KBAC-29: Designed to accept single-phase

(Terminals “L1”, “L2”) or 3-phase (Terminals “L1”,

“L2”, “L3”) AC line input. Rated for 208/230 Volt AC

line input only. See Figure 8. (See note above.)

Model KBAC-29(1P): Designed to accept

single-phase AC line input (Terminals “L1”, “L2”).

Rated for 208/230 Volt AC line input only. See

Figure 7 on page 14.

Models KBAC-45, 48: Designed to accept

3-phase AC line input only (Terminals “L1”,

“L2”, “L3”). Rated for 400/460 Volt AC line

input only. See Figure 8.

5.2 Ground Connection – Connect the

Ground Wire (Earth) to the Green Ground

Screw. The Ground Screw is located next to

Terminal Block TB1. See Figure 7 on page

14 and Figure 8.

5.3 Motor Connection – Wire the motor to

Terminal Block TB1 Terminals “U”, “V”, “W”.

See Figure 7 on page 14 and Figure 8.

Motor cable length should not exceed

100 ft (30 m) – special reactors may be

required – consult our Sales Department.

Be sure Jumper J2 is set to the corresponding motor horsepower rating, as described in Section 6.2

on page 18.

5.4 Remote Main Speed Potentiometer Connection – The drive is supplied with a prewired Main

Speed Potentiometer mounted on the front cover.

*Note: model KBAC-29 is rated 2 HP maximum with single-phase AC line input and 3 HP maximum with 3-phase AC line input.

to Terminals "L1", "L2", as shown below.

Model KBAC-29 Only

Wire the single-phase AC line input

208/230 Volt

AC Line Input

Single-Phase, 50/60 Hz

Ground (Earth)

L3

L2

L1

AC LINE

Ground (Earth)

3-Phase, 50/60 Hz

208/230, 400/460 Volt

Motor

AC Line Input

W

U

V

MOTOR

TB1

L1

L3

L2

AC LINE

Figure 8 – Models KBAC-29*, 45, 48 AC Line Input, Motor, and Ground Connections

Figure 9 – Remote Main Speed

Potentiometer Connection

Main Speed

Potentiometer

Orange (Wiper)

Violet (High)

White (Low)

P1

P2

P3

HIGH VOLTAGE!

See Warning on Page 14.

Figure 10 – Remote Start/Stop Switch Connection

with Normally Open Stop Contact

(J9 Installed in “NO” Position)

CO

M

Black

STOP

STOP

Red

START

RUN

White

NO

J9

NC

HIGH VOLTAGE! See Warning on Page 14.