Figure 30 – minimum speed trimpot range, Figure 31 – maximum speed trimpot range, Figure 32 – acceleration trimpot range – KB Electronics KBAC-48 User Manual

Page 23

Advertising
background image

23

a fuse (Littelfuse 312/314, Buss ABC, or equivalent) or a circuit breaker in series with each ungrounded

conductor. Do not fuse motor leads. For the recommended fuse size, see Table 4 on page 10.

Wire the drive in accordance with the National Electrical Code requirements and other local codes that

may apply to the application.

12 DIAGNOSTIC LEDs

The drive contains two diagnostic LEDs mounted on the enclosure cover to display the drive’s

operational status.

12.1 Power On LED (PWR) – The “PWR” LED will illuminate green when the AC line is applied to the drive.

WARNING! Do not depend on the PWR LED as a guaranteed power off condition.

Be sure the main power switch or circuit breaker is in the “OFF” position before

servicing this drive.

12.2 Status LED (ST) – The “ST” LED is a tricolor LED which provides indication of a fault or abnormal

condition. The information provided can be used to diagnose an installation problem such as incor-

rect input voltage, overload condition, and drive output miswiring. It also provides a signal which

informs the user that all drive and microcontroller operating parameters are normal.

Table 7, summarizes the “ST” LED functions.

Table 7 – Drive Operating Condition and Status LED Indicator

Drive Operating Condition

Flash Rate

1

and LED Color

Normal Operation

Slow Flash Green

Overload (120% – 160% Full Load)

Steady Red

2

I

2

t (Drive Timed Out)

Quick Flash Red

2

Short Circuit

Slow Flash Red

Undervoltage

Quick Flash Red / Yellow

3

Overvoltage

Slow Flash Red / Yellow

3

Stop

Steady Yellow

Stand-By

4

Slow Flash Yellow

Input Phase Loss

5

Rapid Flash Yellow

Notes: 1. Slow Flash = 1 second on and 1 second off. Quick Flash = 0.25 second on and 0.25 second off. 2. When the Overload is removed, before
the I

2

t times out and trips the drive, the “ST” LED will flash green. 3. When the Undervoltage or Overvoltage condition is corrected, the “ST” LED

will flash Red / Yellow / Green. 4. Only if the Forward-Stop-Reverse Switch is installed. 5. Model KBAC-29, with three-Phase AC line input, and
Models KBAC-45, 48. Rapid Flash = 4 mSec on and 6 mSec off.

13 TRIMPOT ADJUSTMENTS

The drive contains trimpots which are factory set for most applications. See Figure 2 on page 9 for the

location of the trimpots and their approximate factory calibrated positions. Some applications may

require readjustment of the trimpots in order to tailor the drive for a specific requirement. The trimpots

may be readjusted as described below.

WARNING! If possible, do not adjust trimpots with the main power applied. If adjust-

ments are made with the main power applied, an insulated adjustment tool must be

used and safety glasses must be worn. High voltage exists in this drive. Fire and/or electrocution

can result if caution is not exercised. The Safety Warning on page 5 must be read and understood

before proceeding.

(Shown Factory Set to 0% Frequency Setting)

0

MIN

40

15

35

30

Figure 30 – Minimum Speed

Trimpot Range

(Shown Factory Set to 100% Frequency Setting)

70

MAX

110

75

90
100

80

Figure 31 – Maximum Speed

Trimpot Range

0.3

(Shown Factory Set to 1.5 Seconds)

ACCEL

20

3

1.5

17

10

Figure 32 – Acceleration

Trimpot Range

Advertising
This manual is related to the following products: