Figure 38 – boost trimpot range, Figure 39 – jog trimpot range – KB Electronics KBAC-48 User Manual

Page 26

Advertising
background image

26

13.8 Boost (BOOST) – The drive is factory set for Fixed Boost

(Jumper J6 set to the “FIX” position). When the drive is set for

Adjustable Boost (Jumper J6 set to the “ADJ” position), the BOOST

Trimpot can be used to adjust the amount of boost voltage to the

motor. See Figure 38. Also see Section 6.5 on page 19.

Application Note – The Boost function operates over a frequency

range of 0 – 15 Hz. If the frequency range required is above 15 Hz,

Boost adjustment is not necessary.

WARNING! To avoid motor winding overheating and failure,

do not overboost the motor.

Note: An unloaded motor with excessive boost will draw more

current than a partially loaded motor.

The boost voltage may be adjusted as follows:

1. Wire an AC RMS ammeter in series with one motor phase.

2. Run the motor unloaded at approximately 4 Hz (or 120 RPM).

3. Increase the boost until the ammeter reaches the motor

nameplate rated current (Amps AC).

4. Using the Main Speed Potentiometer, slowly adjust the

motor speed over a 1 – 15 Hz (0 – 450 RPM) range. If the

motor current exceeds the nameplate rating, decrease the boost setting.

13.9 Jog (JOG) – The Jog feature requires the installation of a Run-Stop-Jog Switch. The switch must be

wired according to Figure 39. The JOG Trimpot range is shown in Figure 39.

The orange Main Speed Potentiometer wire (wiper) which connects to Terminal “P2” on the drive

must be removed and installed on Terminal “RUN” on the switch. The “JOG” Terminal on the drive

connects to “JOG” on the switch. Terminal “P2” on the drive connects to the center (common)

terminal on the switch.

When the switch is in the “JOG” position, the JOG Trimpot is used to set the “jog” speed. When the

switch is in the “RUN” position, the Main Speed Potentiometer is used for speed setting.

The Run-Stop-Jog Switch (Part No. 9340) is available as an optional accessory. See Table 2 on page 8.

BOOST

(Shown Factory Set to 5 Volts/Hz)

5
0

8

30

22

15

Figure 38 – Boost

Trimpot Range

35

JOG

(Shown Factory Set to 35% Frequency Setting)

0

25

100

75

50

Figure 39 – Jog

Trimpot Range

Run-Stop-Jog Switch

P3

P2

Orange (Wiper)

(JOG)

(P2)

White (Low) (P1)

Potentiometer

Violet (High) (P3)

Main Speed

CL

JOG

COMP

BOOST

ACCEL

DECEL

JOG

MAX

MIN

P1

J2

Jog Trimpot

(SPDT - Center Off)

(Wiper)

E

D

A

C

B

M
A

J3

Figure 40 – Run-Stop-Jog Switch Connection (SPDT – Center Off)