To operate the drive from a

remote potentiometer (5 kΩ),

remove the white, orange,

and violet potentiometer

leads from Terminals “P1”,

“P2”, and “P3”. The wires may

be taped and left inside the

drive. The potentiometer

assembly may be removed

if a watertight seal is used to

cover the hole in the front

cover. Wire the Main Speed

Potentiometer to Terminals

“P1” (low side), “P2” (wiper),

and “P3” (high side). See

Figure 9 on page 15.

WARNING! Do not earth ground any

Main Speed Potentiometer terminals.

Application Note – If it is required that the Remote

Main Speed Potentiometer be isolated from the AC

line, install the SIAC Signal Isolator (Part No. 9600).

5.5 Remote Start/Stop Switch Connection –

The drive is supplied with a prewired Start/Stop

Switch mounted on the front cover to electronically

start and stop the drive.

To operate the drive from a remote Start/Stop

Switch (type ON-OFF-ON, SPDT), remove the white,

black, and red wires from Terminals “RUN”, “COM”,

and “STOP”. The wires may be taped and left inside

the drive. The switch assembly may be removed if a

liquidtight seal is used

to cover the hole in

the front cover. After

applying power to the

drive, momentarily set

the Start/Stop Switch

to the “START” position.

For Start/Stop Switch

with normally closed

stop contact, set

Jumper J9 to the “NC”

position. See Figure 10

on page 15 and Figure

11. Also see Section 6.8

on page 19.

5.6 Automatic Restart – Automatic restart requires the elimination of the Start/Stop Switch. Remove

the white, black, and red wires from Terminals “RUN”, “COM”, and “STOP”. The wires may be taped

and left inside the drive. The switch assembly may be removed if a liquidtight seal is used to cover

the hole in the front cover.

To eliminate the Start/Stop function, hardwire Terminals ”RUN” and “COM” with the jumper that is

provided. Be sure Jumper J9 is set to the “NO” position. See Figure 12.

WARNING! Using a jumper to eliminate the Start/Stop function will cause the motor to

run at the Main Speed Potentiometer setting when the AC line is applied.

HIGH VOLTAGE! See Warning on Page 14.

NO

J9

NC

CO

M

(Push to Stop)

Normally Closed

Momentary Contact

STOP

STOP

Normally Open

Momentary Contact

(Push to Start)

RUN

START

Figure 11 – Remote Start/Stop Switch Connection

with Normally Closed Stop Contact

(J9 Installed in “NC” Position)

NO

J9

NC

CO

M

STOP

RUN

HIGH VOLTAGE!

See Warning on Page 14.

Figure 12 – Start/Stop Function Eliminated

(Terminals Hardwired) (Jumper Installed)

(J9 Installed in “NO” Position)

HIGH VOLTAGE! See Warning on Page 14.

0 – 5

Volts DC

P2

P3

P1

V

-

+

0 – 10

Volts DC

P2

P3

P1

10k

V

10k

-

+

Figure 13 – Voltage Following Connections (Isolated)