40

Calibration

SPEEDMASTER™ OPERATION MANUAL

8. Remove power from the drive.
9.

Remove the lock from the motor shaft.

10. Remove the ammeter in series with the motor armature.

ACCELERATION (ACCEL)

The ACCEL setting determines the time the motor takes to to
ramp to a higher speed. See

Specifications on page 1 for

approximate acceleration times. The ACCEL setting is factory
set to its minimum value (full CCW).

Turn the ACCEL trimpot CW to increase the acceleration time,
and CCW to decrease the acceleration time.

DECELERATION (DECEL)

The DECEL setting determines the time the motor takes to ramp
to a lower speed. See

Specifications on page 1 for approximate

deceleration times. The DECEL setting is factory set to its
minimum value (full CCW).

Turn the DECEL trimpot CW to increase the deceleration time,
and CCW to decrease the deceleration time.

Calibration procedure conclusion

This concludes the calibration procedure. The control should
now be calibrated for optimum operation.

Advertising