51

Troubleshooting

SPEEDMASTER™ OPERATION MANUAL

Symptom

Possible

Causes

Suggested

Solutions

Fuse blows or circuit
breaker trips

Line fuse does not
blow or circuit breaker
does not trip, but the
motor does not run

1. Line fuses or circuit

breakers are the wrong
size.

2. Motor cable or armature

is shorted to ground.

3. Nuisance tripping caused

by a combination of
ambient conditions and
high-current spikes.

1. Reference signal or

speed adjust pot is set to
zero speed.

2. Reference signal or

speed adjust
potentiometer
connections are open.

1. Check that line fuses or

circuit breakers are the
proper size.

2. Check motor cable and

armature for shorts.

3. Add a blower to cool

the drive components;
decrease TORQUE
settings, or resize
motor and drive for
actual load demand, or
check for incorrectly
aligned mechanical
components or “jams”.
See page 39 for
information on
adjusting the TORQUE
trimpot.

1. Increase reference

signal or speed adjust
potentiometer setting.

2. Check that the

reference signal or
speed adjust
potentiometer
connections are not
open.