Installation instructions – Amana RSS User Manual

Page 18

Advertising
background image

INSTALLATION INSTRUCTIONS

17

RC231002 Rev. 3

Figure 29

The air shutter is located in the lower access area. To

adjust the air shutter, loosen the lock screw. Move the air

shutter to close the opening to decrease the air or enlarge

the opening for more air. Tighten the lock screw when the

adjustment is complete.

OVEN BURNER (RSS)

1.

Orifices

Turn down the orifice hood onto the pin. The orifice

should be turned snug onto the pin being careful not

to drive pin into the valve or to distort the hole through

the center of the pin.

2.

Low Oven Flame Characteristic Adjustment

a. The appearance of a properly adjusted oven burner

flame is a bluish-green inner cone and a dark blue

mantle. The flame characteristics should be clean

and soft with no yellow tips. Blowing or lifting of the

flame should not occur. The burner flame should be

1/2" long when the air shutter is correctly adjusted.

b. An electric ignitor is used to light the burner. DO

NOT attempt to insert any object into the openings of

the protective shield surrounding the ignitor. Do not

attempt to clean this area.

c. The air shutter is located in the lower accessed

area. To adjust the air shutter, loosen the lock screw.

Move the air shutter to close the opening to decrease

the air shutter to close the opening to decrease the air

or enlarge the opening for more air. Tighten the lock

screw when the adjustment is complete.

ULTRA-RAY® BROILER BURNER

An electric ignitor is used to light the burner. DO NOT

attempt to insert any object into the openings of the

protective shield surrounding the ignitor element. Do not

attempt to clean this area.

MODELS WITHOUT SEALED TOP BURNERS

Universal models (Nat or LP) are shipped from the factory

orifices for Nat gas. IF THEY ARE TO BE USED ON LP

GAS, the burner orifice spud must be changed. This will be

found under the plate in the center of the burner box. BE

SURE to use the proper burner spud for the gas in use.

Reinsert Nat. Gas orifice in burner box with louvers facing

to rear of unit.

Nat. Gas

LP Gas

Burner Spud

50

58

(Silver colored for identi-

fication)

MODELS WITH SEALED TOP BURNERS

Universal models (Nat. or LP) are shipped from the factory

orificed for Nat. Gas. IF THEY ARE TO BE USED ON LP

GAS, the burner orifice spud must be changed. This will be

found wired to the inlet pipe behind the storage drawer.

The proper orifice for use on Bottled (LP) gas is silver

colored (Nickel plated) and stamped #58 (drill size). BE

SURE to use the proper burner spud for the gas in use.

Rewire the Natural Gas orifice spuds to the inlet pipe for

future conversion.

TO CONVERT

Remove oven door and storage drawer. Shut off valve on

gas line that runs from the pressure regulator to the gas

valve.

Remove the two (2) screws fastening the broiler burner to

the oven tank at front of burner. Remove the burner by

pulling front end down to expose the burner orifice spud in

the rear wall. Be careful not to break the ignitor. Lay the

burner aside carefully with the screen side up. Replace the

burner orifice spud using a 5/16" nut driver. Reverse the

procedure to reinstall the burner.

BURNER ADJUSTMENT

No gas input adjustment is necessary as the infrared

burner is equipped with a fixed orifice. There is no shutter

to adjust.

The burner may have a hazy or fuzzy appearance when in

operation. This haze may be 3/8" thick, maximum and is

normal for this type of burner.

RANGE FEATURE CHECKOUT

Check all range features, including lights, clocks, etc. for

proper operation.

Advertising