Operation and service procedures – Amana RSS User Manual

Page 39

Advertising
background image

OPERATION AND SERVICE PROCEDURES

Electronic Range Control (ERC) (Models w/Two Piece Control)

RC231002 Rev. 3

38

TO AVOID THE RISK OF ELECTRIC SHOCK, PERSONAL INJURY OR DEATH DISCONNECT POWER

BEFORE SERVICING, UNLESS TESTING REQUIRES IT.

If a higher resistance is indicated disconnect the intercon-

nect harness from the sensor and recheck the sensor

resistance to assure that the problem is in the sensor and

not in the interconnect harness or due to a bad connection.

The following table shows the corresponding resistance for

different oven temperatures.

SENSING ELEMENT

TEMPERTURE

SENSING

RESISTANCE

75°F

1091 ± 5.5 OHMS

350°F

1654 ± 11 OHMS

535°F

2018 ± 16 OHMS

875°F

2652 ± 24 OHMS

Figure 38 - E.R.C. Oven Temperature Sensor

ERC TROUBLESHOOTING FAILURE CODES AND

CALIBRATION

ERC REMOVAL

1.

Shut off power to the range.

2.

Remove the "TIME/TEMP. SET" knob by pulling it off

of the control shaft.

3.

Remove the eight (8) function control buttons by

pulling them out of the ERC.

4.

Remove the two (2) control panel lower trim mounting

screws. Carefully pull the lower trim and control panel

glass towards the front of the range and remove trim

and glass.

5.

Remove the four (4) backguard control panel mount-

ing screws (two (2) each side) and pull the panel

assembly forward. The ERC input and relay drive

voltages can now be tested at the ERC J1 connector

with power applied to the range. (See ERC voltage

tests and Figure 37.) The sensor resistance can also

be checked by removing the J2 connector and insert-

ing the ohmmeter leads into the connector plug

terminals.

6.

To remove the ERC, disconnect the J1 and J2

connectors and remove the four (4) ERC mounting

screws.

ERC VOLTAGE TESTS

1.

Partially remove the ERC from the control panel.

Follow the ERC Removal Procedures, Steps 1 - 5.

2.

To check the input voltage for the vacuum fluorescent

display, insert the AC voltmeter leads into the J1

connector at pins J1-1 and J1-2, and turn on power to

the range.

Figure 25 - Electronic Range Control Pin Identification

A voltage reading of approximately 3.2 VAC should

be indicated. If no voltage is indicated, check for

loose connections, open wire (s) and relay/power

supply circuit board output voltage at pins J1-7 and

J1-8 on the relay board.

3.

To check the input voltage that the ERC uses to drive

the bake/broil relays, insert your AC voltmeter leads

into the J1 connector pins J1-3 and J1-4. A voltage

reading of approximately 20.3 VAC should be indi-

cated. If no voltage or a low voltage is indicated,

check for the input supply voltage at pins J1-3 and J1-

4 (Step 3).

4.

To check the bake relay drive voltage, insert your DC

voltmeter leads into the J1 connector at pins J1-9 and

J1-5, and program the ERC for a bake operation.

Advertising