OPERATION AND SERVICE PROCEDURES

Electronic Range Control (ERC) (Models w/ Two Piece Control)

39

RC231002 Rev. 3

When the ERC initiates the bake operations, a volt-

age reading of approximately 24 VDC should be

indicated. If no voltage is indicated, check for the

input supply voltage at pins J1-3 and J1-4 (Step 3).

5.

To check the broil relay drive voltage, insert your DC

voltmeter leads into the J1 connector at pins J1-8 and

J1-5, and program the ERC for a broil operation.

When the ERC initiates the broil operation, a voltage

reading of approximately 24 VDC should be indi-

cated. If no voltage is indicated, check for the input

supply voltage at pins J1-3 and J1-4 (Step 3).

TO AVOID THE RISK OF ELECTRIC SHOCK, PERSONAL INJURY OR DEATH DISCONNECT POWER

BEFORE SERVICING, UNLESS TESTING REQUIRES IT.