3.

Attach the ohmmeter leads to the P.C. board L1 (TB1)

and N (TB2) terminals. A resistance reading of

approximately one hundred (100) ohms should be

indicated. If zero (0) or infinite ohms is indicated, the

P.C. board must be replaced.

4.

Attach one (1) meter lead to the transformer ground

terminal and the other meter lead to the L1 (TB1)

terminal. Infinite ohms should be indicated. If zero

(0) or a low ohms reading is indicated, replace the

P.C. board.

5.

Remove the meter lead from the L1 (TB1) terminal

and attach it to the N (TB2) terminal. Infinite ohms

should again be indicated. If zero (0) or a low ohms

reading is indicated, replace the P.C. board.

6.

Attach the ohmmeter leads to the K1 relay contact

terminals TB4 and TB5. An infinite ohms reading

should be indicated. If a zero (0) or a low ohms

reading is indicated, replace the P.C. board.

7.

Attach the ohmmeter leads to the K1 relay contact

terminals TB6 and TB7. Infinite ohms should be

indicated. If a zero (0) or low ohms reading is

indicated, replace the P.C. board.

8.

Set the ohmmeter to the RX1 ohms scale and zero the

meter. Attach the meter leads to pins two (2) and

fourteen (14) at the P.C. board J2 20 pin plug block.

A resistance reading of approximately two (2) to three

(3) ohms should be indicated. If an infinite ohms

reading is indicated, replace the P.C. board.

K1 RELAY CONTACT TESTING

1.

Shut off power to the range.

2.

Remove the wire leads from the P.C. board terminals

TB4, TB5, TB6, and TB7. Wrap the wire lead terminal

ends with electrical tape to reduce the possibility of

electrical shock or a short circuit to the range.

3.

Set an ohmmeter to the RX1 scale and connect the

meter leads to P.C. board terminals TB4 and TB5.

4.

Turn on the power to the range and set the clock for

the correct time of day. Contact TB4 - TB5 should be

open (infinite ohms).

6.

Press the "STOP TIME" button.

7.

Press the "UP" button to set the desired stop time of

the self-clean cycle. For example, to have the self-

clean end at 4 o'clock, press and hold the "UP" button

until "4:00" appears on the display, then release the

"UP" button. After approximately five (5) seconds,

the display will revert back to the Time-of-Day and

"AUTO" will appear on the left of the display indicating

the "CLOCK/TIMER" is programmed for an auto-

matic timed operation. The clock will automatically

calculate the start time of the self-clean cycle. In

other words, a three (3) hour self-clean cycle would

begin at one (1) o'clock and end at four (4) o'clock.

When the start time of the self-clean cycle is reached,

the oven indicator in the center of the display will

come on and the clean cycle will begin.

The oven indicator light on the control panel will come

on and cycle ON and OFF with the thermostat. When

the stop time is reached, the oven indicator turns off

and an alarm will sound for approximately ten (10)

seconds. The oven will automatically turn off and

"AUTO" will continue to blink on and off indicating the

Clock/Timer was set for an automatic timed mode

and it is not completed.

8.

After the clean cycle turn the selector switch to

"MANUAL", the oven control to "OFF", and press the

"CLOCK/CANCEL" button.

9.

The oven door can be opened approximately thirty

(30) minutes after the completion of the clean cycle.

Do not attempt to open the oven door latch until

approximately thirty (30) minutes have elapsed, oth-

erwise the door lock mechanism may be damaged.

DO NOT FORCE THE LATCH HANDLE.

If the oven door will not open, wait five (5) minutes and

try again.

CLOCK/TIMER TESTING PROCEDURES

P.C. BOARD TESTING - NO POWER TO UNIT

1.

Shut off power to the range and remove the P.C.

board.

2.

Set ohmmeter to RX10 scale.

TO AVOID THE RISK OF ELECTRIC SHOCK, PERSONAL INJURY OR DEATH DISCONNECT POWER

BEFORE SERVICING, UNLESS TESTING REQUIRES IT.