Chapter 8: Recording Options

PETracer EML User Manual

100

LeCroy Corporation

8.2 General Tab

The General Page presents options that affect all recordings:

PETracer EML in Advanced Mode:

Recording Type: Sets the trigger mechanism for the recording: Snapshot,
Manual Trigger, and Event Trigger.

Target Analyzer: Presents a menu with options for selecting an Analyzer platform:

PETracer Edge

PETracer ML

PETracer ML (2 Units)

PETracer EML

PETracer Summit

Summit T2-16

Buffer Size: Causes the Analyzer to record traffic to its buffer and then upload the CATC
Trace to the host PC. Recordings are limited in size to the size of the Analyzer's buffer
(4 GB per direction).

Trigger Position: Controls the percentage of buffer allocated for pre- and post-buffer
recording.