Teledyne LeCroy PETracer EML Analyzer and Exerciser User Manual User Manual

Page 213

Advertising
background image

PETracer EML User Manual

Chapter 10: Traffic Generation

LeCroy Corporation

205

FCRx Parameter

Values

Default

Comment

Enable Tx Flow Control

Yes
No

Yes

When not set, the TLPs are being sent without
the regard of how many credits are available.
This option prevents TLP transmission if
insufficient credits are available.

Enable Rx Flow Control

In ns

(rounded to nearest 8)
Off

4200

When enabled, allows automatic updating of
these DLLPs.
This option enables a periodic timer that
controls sending of UpdateFC DLLPs. You
should leave timer and credit values to
defaults for correct behavior.

PH

0 to 255

1

Posted Request Headers

NPH

0 to 255

1

Non-Posted Request Headers

CplH

0 to 255

1

Completion Headers

PD

0 to 4095

1024

Posted Request Data Payload

NPD

0 to 4095

1

Non-Posted Request Data Payload

CplD

0 to 4095

1024

Completion Data Payload

Advertising