Target analyzer, Trigger position, Trigger on – Teledyne LeCroy PETracer Summit and Summit T2-16 PCIe User Manual User Manual

Page 131: Target analyzer trigger position trigger on

Advertising
background image

Summit User Manual

Chapter 8: Recording Options

Teledyne

LeCroy

123

Target Analyzer

Target Analyzer presents a menu with these choices:

PETracer Edge: Displays the options for the PETracer Edge Analyzer.

PETracer ML: Displays the options for the PETracer ML Analyzer.

PETracer ML (2 Units): Displays the same options as PETracer ML but lists
Unit 1 and Unit 2 in the Link Section on the right. In a two-unit setup, Unit 1
and Unit 2 are two separate Analyzers linked together by BNC on the back of
the units to form a single, logical Analyzer.

PETracer EML: Displays the options for the PETracer EML Analyzer.

PETracer Summit and Summit T2-16: Displays the options for the PETracer
Summit or Summit T2-16 Analyzer.

Selecting an Analyzer platform changes the options presented in the Link and Events
pages within the Recording Options dialog.

Trigger Position

This Trigger Position slide-bar lets you to adjust the amount of recording buffer allocated
to recording pre-trigger and post-trigger traffic.

For example, if you set the Trigger Position to 90% Post-Triggering Traffic, the Analyzer
records 10% pre-trigger traffic and 90% post-trigger traffic.

Trigger Position is only available when Manual Trigger or Event Trigger is selected.

Trigger On

For Bit Tracer Recording in PETracer Summit or Summit T2-16, the Trigger On section
allows you to select the Upstream and Downstream Symbol on which to trigger from a
drop-down list of bits.

In Simple Mode (see Figure 1), Trigger On allows you to select: Error, Link Up/Link Down.
TS1, TS2, FTS, Any TLP, Config Rd, Config Wr, IO Rd, IO Wr, Mem Rd, Mem Wr,
Message, Completion, InitFC1, InitFC2, ACK, NAK, and/or PM.

Advertising