Teledyne LeCroy Sierra M6-1 SAS_SATA Protocol Analyzer User Manual User Manual
Page 71

Sierra M6‐1 SAS/SATA Protocol Analyzer User Manual
69
Trigger Setup
Teledyne LeCroy
Define Sequential Trigger Mode
This is enabled when more than one pattern is used. It allows for the use of a simple state
machine of “pattern A then pattern B”. When checked, the Count field in each pattern’s
dialog is enabled (see figure below).
Figure 2.36: Count Field Dialog
The SATA Parameters window displays the following trigger pattern categories:
Timer
Timeout
External/Manual Trigger
Device Sleep
Bus Condition
Symbol
Primitive
FIS
FIS Pattern
ATA Command
ATA Command Pattern
ATAPI
Soft Reset
Data Pattern
Protocol Errors
Note:
In packet view, you can right‐click on any frame, select Add to Trigger, and add the pattern to
DataPatternCapture to make it a trigger pattern.
Count field disabled
Count field enabled