Teledyne LeCroy Sierra M6-1 SAS_SATA Protocol Analyzer User Manual User Manual
Page 73

Sierra M6‐1 SAS/SATA Protocol Analyzer User Manual
71
Trigger Setup
Teledyne LeCroy
Figure 2.38: Timeout Dialog
"Start Events" starts the timer in Timeout Trigger and "End Events" triggers the analyzer (if
first trigger mode is selected) or resets the trigger (if second trigger mode is selected).
Repetitions of the Start Events are ignored until the End Event is encountered or the timer
expires.
Select a pattern for Start Events or End Events, enter a Timeout value, then select Trigger
Mode:
If End Events occur before timer expires
If timer expires before End Events
Note:
Timeouts can only be configured from the Timeout Pattern dialog. The Timeout Pattern dialog
allows configuring other patterns as triggers in combination with timeouts. Other pattern dialogs
do not allow configuration of timeouts.