Teledyne LeCroy WaveStation SCPI Command Reference Manual User Manual
Page 18

WaveStation SCPI
Parameters
Value
Description
MEAN
<mean>
Parameter is valid only when WVTP is NOISE. Where <mean>:= {default unit is
V; range depends on <standard deviation>}.
WIDTH
<width>
Value of width. Parameter is valid only when WVTP is PULSE.
RISE
<rise>
Value of rise. Parameter is valid only when WVTP is PULSE.
FALL
<fall>
Value of fall. Parameter is valid only when WVTP is PULSE.
DLY
<delay>
Where <delay>:= {default unit is S; minimum 0, maximum is Pulse Period}.
Parameter is valid only when WVTP is PULSE.
QUERY SYNTAX
<channel>:BaSicWaVe?
<channel>:=
{C1|C2}
RESPONSE
<channel>:BSWV <type>,<frequency>,<offset>,<amplifier>,<duty>,
<symmetry>,<phase>
EXAMPLE 1
Set Channel 1 basic wave type to Ramp.
C1:BSWV WVTP,RAMP
EXAMPLE 2
Set Channel 1 signal frequency to 2000Hz.
C1:BSWV FRQ,2000HZ
EXAMPLE 3
Retrieve Channel 1 Basic Wave settings.
C1:BSWV?
Return:
C1:BSWV TYPE,SINE,FRQ,1000,AMP,3,OFST,3
RELATED
ARWV, BTWV, CFG, CPL, MDWV, SWWV
16
922829 Rev C