Vanguard CT-7000 S3 User Manual

Page 34

Advertising
background image

CT-7000 S3 USER’S MANUAL

REV 1

29

e. The following screen will be displayed:

1. PERCENT OF STROKE

Press the

[1]

key (PERCENT OF STROKE) to set the open analysis point #2 as a

percentage of the total stroke value. The following screen will be displayed:

Type the percentage value using the numeric keypad and then press the

[ENTER]

key. The analysis points will be set and you will be returned to the “START-UP”
menu.

2. DIST FROM CLOSE

Press the

[2]

key (DIST FROM CLOSE) to set the open analysis point #2 as a distance

from the contact’s close position. The following screen will be displayed:

Type the distance value using the numeric keypad and then press the

[ENTER]

key.

The analysis points will be set and you will be returned to the “START-UP” menu.

3. CONTACT +/- TIME

Press the

[3]

key to select the CONTACT +/- TIME option. The following screen will

be displayed:

OPEN ANALYSIS PT 2

1. CONTACT PLUS TIME
2. CONTACT MINUS TIME

OPEN ANALYSIS PT 2

VALUE: 000.0 IN

DISTANCE FROM CLOSE


"ENTER" TO CONFIRM

OPEN ANALYSIS PT 2

%

of total stroke

00

%


"ENTER" TO CONFIRM

OPEN ANALYSIS PT 2

1. PERCENT OF STROKE
2. DIST FROM CLOSE
3. CONTACT +/- TIME

Advertising