e. If the selected test included an excitation test, the following screen will be displayed:

Select the maximum test current for the excitation test by pressing the corresponding
key (

[1]

-

[6]

).

NOTE

Most CT’s will saturate before the excitation current reaches 1A. To reduce
stress on CT’s, a maximum test current of 1A is recommended.

f. If the selected test included a ratio test, the following screen will be displayed:

1. YES

Press the

[1]

key if you would like to enter the CT nameplate values. The

following screen will be displayed:

Type the first number using the keypad.

You can press the

[CLEAR]

key to restart a field entry if necessary.

Press the

[ENTER]

key. The following screen will be displayed:

Type the second number using the keypad. The screen will be updated as shown:

Press the

[ENTER]

key. Continue to step g.

ENTER PLATE RATIO:

1000 : 5.0

ENTER PLATE RATIO:

1000 : 0.0

ENTER PLATE RATIO:

0 :

XFMR NAME PLATE RAT.

1. YES
2. NO

SET TEST CURRENT:
1. 0.2A 2. 0.5A
3. 1A 4. 2A
5. 5A 6. 10A

Advertising