Page 50

Figure 4-6: COM 3 Function Select Jumper Location

4.6.4 LCD Voltage Select

WARNING:

Incorrect voltages can destroy the LCD panel. Make sure to select a

voltage that matches the voltage required by the LCD panel.

Jumper Label:

JP5

Jumper Type:

3-pin header

Jumper Settings:

See

6

Table 4-5

Jumper Location:

See

6

Figure 4-7

The LCD voltage selection jumper sets the voltage of the power supplied to the LCD

panel.

Setting Description

Short 1-2

+3.3 V (Default)

Short 2-3

+5.0 V

Table 4-5: LVDS Voltage Selection Jumper Settings