NANO-9452 EPIC Motherboard

Page 120

 19200

8,n,1

 09600

8,n,1

NOTE:

Identical baud rate setting musts be set on the host (a management

computer running a terminal software) and the slave

Flow Control [None]

Use the Flow Control option to report the flow control method for the console redirection

application.



None D

EFAULT

No control flow,

Hardware

Hardware is set as the console redirection

Software

Software is set as the console redirection

Redirection After BIOS POST [Always]

Use the Redirection After BIOS POST option to specify when console redirection should

occur.



Disabled

The console is not redirected after POST

Boot Loader

Redirection is active during POST and during Boot

Loader

Always

D

EFAULT

Redirection is always active (Some OSes may not

work if set to Always)

Terminal Type [ANSI]

Use the Terminal Type BIOS option to specify the remote terminal type.



ANSI D

EFAULT

The target terminal type is ANSI

VT100

The target terminal type is VT100