8 powering on/off the system, 9 redundant power, Owering – IEI Integration TANK-800-D525 v1.14 User Manual

Page 52: Ff the, Ystem, Edundant, Ower, Figure 3-31: power button

Advertising
background image

TANK-800 Embedded System

Page 40

3.8 Powering On/Off the System

WARNING:

Make sure a power supply with the correct input voltage is being fed into

the system. Incorrect voltages applied to the system may cause damage to

the internal electronic components and may also cause injury to the user.

ƒ

Power on the system: press the power button for 3 seconds

ƒ

Power off the system: press the power button for 6 seconds

Figure 3-31: Power Button

3.9 Redundant Power

The TANK-800 is a system that supports redundant power. The redundant power input

increases the reliability of the system and prevents data loss and system corruption from

sudden power failure. The system can instantly and uninterruptedly switch to the second

power input when the main power is unavailable or in low voltage capacity.

There are two power connectors on the rear panel. Power 1 connector is a 3-pin terminal

block that supports ACC On signal. Power 2 connector is a DIN connector that can directly

connect to a power adapter. The supported power input voltages are: