TANK-800 Embedded System

Page 41

ƒ

Power 1 (terminal block): 9 V (+/-0.3 V) ~ 36 V

ƒ

Power 2 (DC jack): 10.5 V (+/-0.3 V) ~ 36 V

Figure 3-32: Power Connectors

When the system is in ACC On mode, the main power input is from Power 1 connector;

when the system is in ACC Off mode, the main power input is from Power 2 connector. The

ACC on/off mode is selected by the ACC mode switch on the rear panel (Figure 3-15).

The following sections describe how the redundant power works in ACC On mode and

ACC Off mode.

3.9.1 ACC ON

NOTE:

In ACC On mode, the Power 1 connector must connect to ACC on

signal to be able to control the system power.

The ACC On mode is designed for vehicle applications. When the TANK-800 is in ACC

On mode, the main power input is Power 1 connector and the backup power is from Power

2 connector.

Advertising