TANK-800 Embedded System

Page 42

3.9.1.1 Boot-up

When both power connectors are connected to power source with over 9 V power input,

the two power LEDs on the front panel remain off until the ACC ON signal jump from

low to high

. The user can choose to use AT power mode or ATX power mode to control

the system. The following flow diagrams show the boot-up process and the LED status in

AT and ATX power modes.

Figure 3-33: ACC On: AT Mode

Figure 3-34: ACC On: ATX Mode

3.9.1.2 Switch to Backup Power

During the operation, the system power will switch from Power 1 to Power 2 automatically

when the following situations occur:

ƒ

Power 1 < 9V and Power 2 > 10.5V

ƒ

Power 1 > 9V, but the ACC ON signal jump from high to low

ƒ

Power 1 is unplugged and Power 2 > 10.5V

The following flow diagram shows how the power is switched between Power 1 and

Power 2 and their LED statuses.