5.1 Installation Precautions

When installing the SRM series industrial monitor, please follow the precautions listed

below:

ƒ Read the user manual: The user manual provides a complete description of

the SRM series industrial monitor, installation instructions and configuration

options.

ƒ DANGER! Disconnect Power: Power to the monitor must be disconnected

when installing the SRM series industrial monitor, or before any attempt is

made to access the rear panel. Electric shock and personal injury might occur

if the rear panel of the monitor is opened while the power cord is still

connected to an electrical outlet.

ƒ Qualified Personnel: The SRM series industrial monitor must be installed

and operated only by trained and qualified personnel. Maintenance, upgrades,

or repairs may only be carried out by qualified personnel who are familiar with

the associated dangers.

ƒ Mounting: Since the monitor may weigh up to 10 kg (not including a swing

arm or other accessories), please ensure at least two people assist with

mounting the monitor.

ƒ Air Circulation: Make sure there is sufficient air circulation when installing the

monitor. The monitor’s cooling vents must not be obstructed by any objects.

Blocking the vents can cause overheating of the monitor. Leave at least 5 cm

of clearance around the monitor to prevent overheating.

ƒ Grounding: The monitor should be properly grounded. The voltage feeds

must not be overloaded. Adjust the cabling and provide external overcharge

protection per the electrical values indicated on the label attached to the back

of the monitor.

ƒ Anti-static Discharge: The rear panel of the monitor must to be removed to

configure the monitor’s AD board voltage select jumper. When doing so, be

sure the monitor is disconnected from its power source and take all necessary

safety precautions to avoid electrocution and static discharge to the AD board.

The use of a grounded wrist strap and an anti-static work pad is

recommended.