2 changing the default settings – IEI Integration SRM_121_150 v2.02 User Manual

Page 72

Advertising
background image

SRM Series/SRM-KIT Series Monitor

Page 62

The Figure 6-5 shows the SRM-121 default linearity of the LCD backlight and ambient

light. When the sensor detects the ambient illuminance as 5200 LUX or above, the SRM

series industrial monitor adjusts the LCD brightness to 100%.

100%

90%

80%

70%

60%

50%

40%

30%

20%

10%

0%

100%

100%100%

100%100%

0

100

200

300

400

500

600

700

800

900

1000

0

500

1000

1500

2000

2500

3000

3500

4000

4500

5000

10000

15000

20000

25000

30000

35000

40000

Ambient Light (LUX)

LCD Brightness (cd/m2)

Figure 6-5: SRM-121 Default Linearity of the LCD Backlight and Ambient Light

6.2.4.2 Changing the Default Settings

The maximum and minimum LUX value and backlight brightness in the OSD panel can be

adjusted to meet custom needs and lighting conditions.

NOTE:

When the auto dimming function is on, the “Brightness Control” in main

display feature (refer to Section 6.2.1) is not effective. The user can only

adjust the maximum and minimum value of the LUX and backlight to make

the LCD brighter or darker.

Light Max. and Light Min.

To keep the LCD brightness within a specific range, not the 0~100% wide range, adjust

the minimum and maximum value of the LCD backlight. For example, set the Light Min. to

Advertising