IEI Integration EP-308A v1.12 User Manual

Page 52

Advertising
background image

EP-308A POS

Page 42

Î

PWM Manual mode

The fan spins at the speed set in:

Fan

PWM

control

ƒ

Temp. Limit of OFF [000]

WARNING:

CPU failure can result if this value is set too high

The fan will turn off if the temperature falls below this value.

ƒ

Minimum Value: 0°C

ƒ

Maximum Value: 127°C

ƒ

Temp. Limit of Start [020]

WARNING:

CPU failure can result if this value is set too high

When the fan is off, it will only start when the temperature exceeds this setting.

ƒ

Minimum Value: 0°C

ƒ

Maximum Value: 127°C

ƒ

Start PWM [070]

This is the initial speed of the fan when it first starts spinning.

ƒ

PWM Minimum Mode: 0

ƒ

PWM Maximum Mode: 127

ƒ

Slope PWM [1 PWM]

A bigger value will increase the fan speed in big amounts. A smaller value will increase the

speed more gradually.

Advertising