Installation, Input connection, Input fuse and supply wire considerations – Lincoln Electric IM10029 POWER WAVE S350CE User Manual

Page 13: Input voltage selection, Power cord replacement, Warning

Advertising
background image

A-4

INSTALLATION

POWER WAVE® S350CE

A-4

INPUT CONNECTION

Only a qualified electrician should
connect the input leads to the
POWER WAVE® S350CE.
Connections should be made in
accordance with all local and

national electrical codes and the connection dia-
grams. Failure to do so may result in bodily injury
or death.

-------------------------------------------------------------

A 15 ft. (4.5m) power cord is provided and wired into
the machine.

For Three Phase Input

Connect green lead to ground per National Electric
Code.

Connect black, grey and brown leads to power.

INPUT FUSE AND SUPPLY WIRE
CONSIDERATIONS

Refer to Specification Section for recommended fuse,
wire sizes and type of the copper wires. Fuse the
input circuit with the recommended super lag fuse or
delay type breakers (also called "inverse time" or
"thermal/magnetic" circuit breakers). Choose input
and grounding wire size according to local or national
electrical codes. Using input wire sizes, fuses or cir-
cuit breakers smaller than recommended may result in
"nuisance" shut-offs from welder inrush currents, even
if the machine is not being used at high currents.

INPUT VOLTAGE SELECTION

The POWER WAVE® S350CE automatically adjusts
to work with different input voltages. No reconnect
switches settings are required.

The POWER WAVE® S350CE
ON/OFF switch is not intended as a
service disconnect for this equip-
ment. Only a qualified electrician
should connect the input leads to

the POWER WAVE® S350CE. Connections should
be made in accordance with all local and national
electrical codes and the connection diagram locat-
ed on the inside of the reconnect access door of
the machine. Failure to do so may result in bodily
injury or death.

------------------------------------------------------------------------

POWER CORD REPLACEMENT

Only a qualified electrician should
connect the input leads to the
POWER WAVE® S350CE.
Connections should be made in
accordance with all local and

national electrical codes and the connection dia-
grams. Failure to do so may result in bodily injury
or death.

------------------------------------------------------------------------

If the input power cord is damaged or needs to be
replaced, remove right case side and remove cord
from CE filter mounted to center divider shown in fig-
ure A.1.

ALWAYS CONNECT THE POWER WAVE GROUND-
ING LUG
(LOCATED AS SHOWN IN FIGURE A.1)
TO A PROPER SAFETY (EARTH) GROUND.

FIGURE A.1

WARNING

WARNING

WARNING

INPUT
POWER
CORD

GROUND
LUG

CE
FILTER

Advertising