A-11

INSTALLATION

POWER WAVE® S350CE

A-11

CONTROL CABLE CONNECTIONS

General Guidelines

Genuine Lincoln control cables should be used at all
times (except where noted otherwise). Lincoln cables
are specifically designed for the communication and
power needs of the Power Wave® / Power Feed®
systems. Most are designed to be connected end to
end for ease of extension. Generally, it is recom-
mended that the total length not exceed 100ft.
(30.5m). The use of non-standard cables, especially in
lengths greater than 25 feet, can lead to communica-
tion problems (system shutdowns), poor motor accel-
eration (poor arc starting), and low wire driving force
(wire feeding problems). Always use the shortest
length of control cable possible, and DO NOT coil
excess cable.

Regarding cable placement, best results will be
obtained when control cables are routed separate
from the weld cables. This minimizes the possibility of
interference between the high currents flowing
through the weld cables, and the low level signals in
the control cables. These recommendations apply to
all communication cables including ArcLink® and
Ethernet connections.

Product specific Installation Instructions

Connection Between Power Source and ArcLink®
Compatible Wirefeeders (K1543 – ArcLink Control
Cable)

The 5-pin ArcLink control cable connects the power
source to the wire feeder. The control cable consists
of two power leads, one twisted pair for digital com-
munication, and one lead for voltage sensing. The 5-
pin ArcLink connection on the Power Wave® S350CE
is located on the rear panel above the power cord and
on the front of machine. The control cable is keyed
and polarized to prevent improper connection. Best
results will be obtained when control cables are routed
separate from the weld cables, especially in long dis-
tance applications. The recommended combined
length of the ArcLink control cable network should not
exceed 200ft. (61.0m).

Connection Between Power Source and Ethernet
Networks

The Power Wave® S350CE is equipped with an
ODVA compliant RJ-45 Ethernet connector, which is
located on the rear panel. All external Ethernet equip-
ment (cables, switches, etc.), as defined by the con-
nection diagrams, must be supplied by the customer.
It is critical that all Ethernet cables external to either a
conduit or an enclosure are solid conductor, shielded
cat 5e cable, with a drain. The drain should be
grounded at the source of transmission. For best
results, route Ethernet cables away from weld cables,
wire drive control cables, or any other current carrying
device that can create a fluctuating magnetic field. For
additional guidelines refer to ISO/IEC 11801. Failure
to follow these recommendations can result in an
Ethernet connection failure during welding.