Troubleshooting, Caution input control board – Lincoln Electric IM10029 POWER WAVE S350CE User Manual

Page 34

Advertising
background image

E-4

TROUBLESHOOTING

E-4

POWER WAVE® S350CE

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

INPUT CONTROL BOARD

Error Code #

331 Peak input current limit

333 Under-voltage lockout

336 Thermal Fault

337 Pre-charge timeout

346 Transformer primary over current

Other

Indication

Input current limit has been exceeded. Typically indicates short
term power overload. If problem persists contact Service
Department.

+15 VDC supply on Input control board too low. Verify input voltage
is within the acceptable range. If problem persists contact service
department.

Thermostat on primary module tripped. Typically caused by bottom
fan not working.

Problem with start-up sequence. If problem persists contact Service
Department.

Transformer current too high. Typically indicates short term power
overload. If problem persists contact service department.

Contact the Service Department.