Troubleshooting, Caution – Lincoln Electric IM10029 POWER WAVE S350CE User Manual

Page 38

Advertising
background image

E-8

TROUBLESHOOTING

E-8

POWER WAVE® S350CE

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Cannot Connect

Connection Drops while welding

1. Physical connection.

2. IP address information.

3. Ethernet Speed

1. Cable Location

1. Verify that the correct patch cable

or cross over cable is being used
(refer to local IT department for
assistance).

1a. Verify the cables are fully insert-

ed into the bulk head connector.

1b. The LED under the PC board

ethernet connector will be lit
when the machine is connected
to another network device.

2. Use the appropriate PC utility to

verify the correct IP address infor-
mation has been entered.

2a. Verify no duplicate the IP

addresses exist on the network.

3. Verify that the network device

connected to the Power Wave is
either a 10-baseT device or a
10/100-baseT device.

1. Verify Network cable is not locat-

ed next to current carrying con-
ductors. This would include input
power cables and welding output
cables.

Ethernet

Advertising