Pumptec ELECTRIC SPRAYER 12V User Manual

Page 11

Advertising
background image

11

Version 110112

Pumptec Operating Instructions and Parts Manual

12V ELECTRIC SPRAYER

through the lengths of hose. For example, a 3 gPM system will

require (lose) 50 PSI per 50 ft. of 3/8” ID hose. A pump with only

60-70 PSI may not provide the desired performance at the end of

the hose. See reference charts to assist in system design.

MAINteNANce

DISASSEMBlY AnD REASSEMBlY

InSTRUCTIOnS (Refer to Schematic)

1. Remove pump from motor using a 3/16” hex wrench for

Model 348U, and use 5/16” hex wrench for Model 20C832.

Remove bolts at each end of pump. Turn pump over so manifold

is facing upward. Place manifold to side as a reference for

reassembly.

Figure 1

2. Holding each head, pull them apart to remove plunger.

Remove retaining plate from pump head. Remove internal seal

parts with finger. Discard parts, keeping the head and retainer

plate.

Figure 2

3. Clean the head with a rag or towel inspect for damage or ex-

cess corrosion. If the head is damaged, do not rebuild. note the

order and orientation of repair parts prior to installation.

4. Place one O-ring support, u-cup and u-cup support ring into

bore. Verify that u-cup support ring is flush with top of u-cup.

Place guide O-ring around guide and lightly grease. Press

guide with O-ring installed into bore. Place retainer O-ring into

recessed area around top of bore.

Figure 3

5. Place vacuum seal O-ring around vacuum seal. lightly grease

O-ring and press into recess in retaining plate. Be careful to apply

even pressure and eliminate bulges in O-ring.

Figure 4

6. grease edge of retaining plate and slide into place. If large re-

tainer O-ring dislodges, do not slide plate, but push O-ring back

into place before sliding into place completely.

Figure 5

7. Repeat the previous steps 3-5 with the other head.

8. lightly grease the plunger with provided grease in small clear

Advertising