Pumptec ELECTRIC SPRAYER 12V User Manual

Page 5

Advertising
background image

5

Version 110112

Pumptec Operating Instructions and Parts Manual

12V ELECTRIC SPRAYER

7. Allow time for air to purge from pump system and return to

tank

8. Close bypass/agitation valve completely to pressurize system

9. Adjust pressure to desired level with adjusting cap

10. Squeeze trigger to clear hose of air and begin spraying. note

pressure while spraying.

11. Adjust regulator to no more than 10-15 psi higher than spray

pressure. Excess pressure will drain battery unnecessarily.

12. When initial star-up is completed:

Push On-Off switch to OFF position

Rotate Power Selector to “OFF” to avoid accidental

operation or unnecessary batery drain

13. Empty tank of water
Read and understand the many features of battery charger.

Refer to enclosed battery charger information for more details

regarding settings and features.

PUMP OPERATIng InSTRUCTIOnS FOR SYSTEMS

Each Pumptec system is tested and inspected prior to shipment

from our facility in Minnesota. This routine includes setting

the pressure to optimum performance levels. Only though

tampering or extremes during shipment should a unit need

pressure adjustment upon arrival to end-user. If you see

shipping issues call Pumptec Inc at 763.433.0303 immediately.
We recommend that you perform an initial set up and test of

your system with clean water to check for leaks. DO nOT install

chemicals before completely testing pumping module and all

connections.

Note:

AlWAYS flush and rinse system after every use. nEVER

change chemicals without completely rinsing tank and whole

pumping system. AlWAYS read chemical label and exactly

follow recommendations for system flushing.
1. Check your water and chemical supply, and then check the

supply in the tank.

2. Do you have adequate filtration? Check line strainer/filter

to make sure it is clean and free of debris.

3. If it is necessary to disassemble the filter to inspect r clean,

be certain to seat the gasket properly, along with the screen

and tighten extra firmly. Any air leakage at the point will

cause drop in pressure and loss of pump prime. It may be

necessary to lubricate gasket prior to re-assembly.

4. Check all plumbing connections to make sure they are tight
5. Check your power source. Make sure your power source is

connected correctly

6. To prime your pump open prime valve on regulator
7. Start pump ( pull on-off switch out) and allow air to purge

from system which usually takes 5-15 seconds

Note:

The pressure may be factor set as a result of the

water/chemical flow restriction to the OEM system. Changing

tips or guns will affect system performance.
8. Hold trigger open on spray gun and start pump. Allow all air

to purge from system and liquid to spray. Trigger the spray

gun a few times to check pressure and nozzle function.

If you are pleased with the spraying pressure and nozzle

performance you will nOT need to make any adjustments.

9. With spray gun triggered, you can adjust the spraying

pressure by adjusting the regulator valve.

Note:

nEVER adjust to a back pressure greater than machine

rating.
There are two easy ways to lower your pressure:
• Turn the regulator knob counter clockwise
• Change to larger size nozzle tip and then adjust the regulator

to 5-10 psi above spray pressure

Note:

The opposite of either will raise the pressure to

maximum pressure setting of the regulator.

10. Adjust the nozzle tip on the gun supplied

Note:

higher pressure requires more amperage. Use only the

pressure you need. Do not unnecessarily overload system.

Should the system overload, a breaker will trip resulting in a