Pumptec ELECTRIC SPRAYER 12V User Manual
Page 4
4
Version 110112
Pumptec Operating Instructions and Parts Manual
12V ELECTRIC SPRAYER
positive displacement pumps providing a specific amount of
fluid constantly while operating. This volume of fluid must
be directed out thru a nozzle or back to a tank because it
cannot be stopped completely without creating excessively
high pressure and risk of damage to pump, components,
property and person. It is recommended a safety device such
as a regulating valve be installed directly on pump head as
protection in case of a failure of another component. Pressure
switches can be used to automate pump operation, but they
must have a pressure regulating device installed as a safety
device.
Fluid can enter a pump either from a filtered tank or
pressurized fluid line.
It is common to use a tank with pumps that are mounted above
the pump. Filtration is important to maintain proper function
of the pump and system. The extent of filtration may be greater
based upon some uses such as misting with ultra-fine nozzles.
ASSEMBlY OPERATIng InFORMATIOn
Proper care must be taken during electrical connection to
battery and/or vehicle. Wiring into the vehicle’s 12V system
should be done by qualified personnel. Use proper gauge wire.
Pumptec Inc. shall bear nO liability or responsibility in how
purchaser and/or their installer wires and installs the system
into a vehicle and they bear all losses associated with any
malfunctions or other potential damages of any kind that could
occur.
nOTE: It is not necessary to wire the sprayer into the vehicle to
use.
To receive the maximum benefit from sprayer, Pumptec
recommends use of a high quality 27 series, deep cycle battery
(not included). For an excellent resource regarding batteries,
chargers and battery systems, please go to http://www.
schumacherproducts.com/applications .
Connect ring terminals accordingly to polarity, color and
size. Red wire with large ring terminals are positive (+) and
connect to positive pole of battery. Black wires with smaller
ring terminals are negative (-) and connect to negative pole of
battery. . Pumptec Inc. bears no liability or responsibility for
this installation.
Refer to Vehicle’s Owner’s Manual for guidance regarding
bolting and securing to vehicle. The sprayer has several
slotted holes in the frame to permit secure mounting to
vehicle. Pumptec Inc. bears no liability or responsibility for this
installation.
STARTUP AnD OPERATIOn
1. Fill tank ½ full with water. Do not fill with chemical for initial
start-up. nEVER fill with flammables.
2. Connect spray gun to end of spray hose and make sure the
trigger is closed
3. Rotate Power Selector to correct position before pulling
On-Off switch. The sprayer is prewired for position “1”
to be on-board battery. Your sprayer may have a red box
switch. Turn that to the On position. Other positions will be
determined based upon whether installation was made into
your vehicle’s electrical system.
The power selector’s switch is nOT an On-Off switch. Use
of power selector switch in this way will damage it and void
warranty.
4. Open ball valve next to line strainer and verify that liquid
flows into strainer
5. Refer to 9025 Multi-Function Control Valve - Open bypass/
agitation valve
6. Pull On-Off switch to start sprayer