Pumptec ELECTRIC SPRAYER 12V User Manual

Page 4

Advertising
background image

4

Version 110112

Pumptec Operating Instructions and Parts Manual

12V ELECTRIC SPRAYER

positive displacement pumps providing a specific amount of

fluid constantly while operating. This volume of fluid must

be directed out thru a nozzle or back to a tank because it

cannot be stopped completely without creating excessively

high pressure and risk of damage to pump, components,

property and person. It is recommended a safety device such

as a regulating valve be installed directly on pump head as

protection in case of a failure of another component. Pressure

switches can be used to automate pump operation, but they

must have a pressure regulating device installed as a safety

device.
Fluid can enter a pump either from a filtered tank or

pressurized fluid line.
It is common to use a tank with pumps that are mounted above

the pump. Filtration is important to maintain proper function

of the pump and system. The extent of filtration may be greater

based upon some uses such as misting with ultra-fine nozzles.

ASSEMBlY OPERATIng InFORMATIOn

Proper care must be taken during electrical connection to

battery and/or vehicle. Wiring into the vehicle’s 12V system

should be done by qualified personnel. Use proper gauge wire.

Pumptec Inc. shall bear nO liability or responsibility in how

purchaser and/or their installer wires and installs the system

into a vehicle and they bear all losses associated with any

malfunctions or other potential damages of any kind that could

occur.

nOTE: It is not necessary to wire the sprayer into the vehicle to

use.
To receive the maximum benefit from sprayer, Pumptec

recommends use of a high quality 27 series, deep cycle battery

(not included). For an excellent resource regarding batteries,

chargers and battery systems, please go to http://www.

schumacherproducts.com/applications .
Connect ring terminals accordingly to polarity, color and

size. Red wire with large ring terminals are positive (+) and

connect to positive pole of battery. Black wires with smaller

ring terminals are negative (-) and connect to negative pole of

battery. . Pumptec Inc. bears no liability or responsibility for

this installation.
Refer to Vehicle’s Owner’s Manual for guidance regarding

bolting and securing to vehicle. The sprayer has several

slotted holes in the frame to permit secure mounting to

vehicle. Pumptec Inc. bears no liability or responsibility for this

installation.

STARTUP AnD OPERATIOn
1. Fill tank ½ full with water. Do not fill with chemical for initial

start-up. nEVER fill with flammables.

2. Connect spray gun to end of spray hose and make sure the

trigger is closed

3. Rotate Power Selector to correct position before pulling

On-Off switch. The sprayer is prewired for position “1”

to be on-board battery. Your sprayer may have a red box

switch. Turn that to the On position. Other positions will be

determined based upon whether installation was made into

your vehicle’s electrical system.

The power selector’s switch is nOT an On-Off switch. Use

of power selector switch in this way will damage it and void

warranty.
4. Open ball valve next to line strainer and verify that liquid

flows into strainer

5. Refer to 9025 Multi-Function Control Valve - Open bypass/

agitation valve

6. Pull On-Off switch to start sprayer

Advertising