Winch mounting – Ramsey Winch DCS-200 SPEED REDUCER - EZ ANCHOR User Manual

Page 5

Advertising
background image

5

Isolated Motor Ground

For non-grounded chassis applications
a jumper wire (#440315) is required to
ground the solenoid assembly.

WINCH MOUNTING

It is most important that this winch be mounted securely so that the three major sec-
tions (the clutch housing end, the cable drum and the gear housing end) are properly
aligned.

All standard model DC-200 Series Winches are furnished with recommended mount-
ing angles. Angle size is 1/4 x 2-1/2 x 2-1/2 x 36” Lg. high strength (50,000 PSI yield)
steel angle.

ELECTRICAL CONNECTIONS
See dimensional drawing on page 18. Using a power cable with appropriate end
terminals, connect the positive (+) battery terminal to the 5/16” dia. stud on the plastic
solenoid cover on the winch. In applications where the chassis is non-grounded, a
jumper wire (#440315) will be required between the winch and the motor ground. This
ground is required to insure a suffi cient ground to operate the solenoid assembly (see
diagram below).

IMPORTANT: hold inner nut on stud with a wrench while tightening outer nut. Using a
ground cable with appropriate end terminals, connect the negative(-) battery terminal
to the motor isolated ground terminal.

SEE ILLUSTRATION

JUMPER CABLE (#440315) MUST BE

INSTALLED ON WINCH FROM MOTOR
ISOLATED GROUND STUD TO GEAR
HOUSING COVER BOLT AS SHOWN
FOR NON GROUNDED CHASSIS

APPLICATIONS.

BELOW

NEGATIVE BATTERY POST

GROUND CABLE

WINCH WILL NOT OPERATE UNLESS
GROUND CABLE IS INSTALLED FROM THE

ISOLATED GROUND TERMINAL TO THE
NEGATIVE BATTERY POST.
(SEE DIAGRAM BELOW)

ISOLATED GROUND

TERMINAL

WINCH MOUNTING

Advertising