background image

CONDITION

CORRECTION

POSSIBLE CAUSE

7

MOTOR RUNS EXTREMELY
HOT.

MOTOR RUNS, BUT WITH
INSUFFICIENT POWER, OR

WITH LOW RPM.

1. Long period of operation.

2. Insuffi cient battery.

3. Electrical cables from
battery to speed reducer
too small.

4. Bad electrical connections.

5. Insuffi cient charging system.

1. Cooling-off periods are essen-

tial to prevent over-heating.

2. Check battery terminal volt

age under load. If 10 volts or

less, replace or parallel another

battery to it at motor terminal.

3. Must be #2 Ga. Wire for

distances up to 15 feet from

battery to speed reducer. Use

larger than #2 Ga. For

distances greater than 15 feet.

4. Check all connections for

looseness or corrosion;

Tighten, clean and grease.

5. Insuffi cient charging system.

1. MOTOR WILL NOT OPER-
ATE.

1. Inoperative solenoid or
stuck

solenoid

2. Inoperative switch.

3. Inoperative motor.

4. Loose connections.

1. Jar solenoid to free contacts.

Check by applying 12 volts to coil

terminal (it should make an

audible click when energized)

2. Disengage speed reducer clutch

or remove armature lead.

Remove switch plug from hood.

Raise connector cover on hood

and with a screw driver, short the

bottom two pins. Solenoid should

click. Short the two left hand pins.

Solenoid should click. Short the

two left pins. The other solenoid

should operate. If both solenoids

operate check for a broken wire in

switch

cable.

3. If solenoids operate, check for

voltage at armature post; replace

motor.

4. Tighten connections on bottom

side of hood and on motor.

Advertising