115

LW9222

Current access classes

16-bit binary

Indicates the Access Classes currently

allowed. Bit 0 indicates Class A; Bit 5

indicates Class F.

LW9500,

LW9501

New password, user 1

32-bit unsigned

Loaded into security system when

LB9061 is set momentarily

LW9502,

LW9503

New password, user 2

32-bit unsigned

Loaded into security system when

LB9061 is set momentarily

LW9504,

LW9505

New password, user 3

32-bit unsigned

Loaded into security system when

LB9061 is set momentarily

LW9506,

LW9507

New password, user 4

32-bit unsigned

Loaded into security system when

LB9061 is set momentarily

LW9508,

LW9509

New password, user 5

32-bit unsigned

Loaded into security system when

LB9061 is set momentarily

LW9510,

LW9511

New password, user 6

32-bit unsigned

Loaded into security system when

LB9061 is set momentarily

LW9512,

LW9513

New password, user 7

32-bit unsigned

Loaded into security system when

LB9061 is set momentarily

LW9514,

LW9515

New password, user 8

32-bit unsigned

Loaded into security system when

LB9061 is set momentarily

LW9516,

LW9517

New password, user 9

32-bit unsigned

Loaded into security system when

LB9061 is set momentarily

LW9518,

LW9519

New password, user 10

32-bit unsigned

Loaded into security system when

LB9061 is set momentarily

LW9520,

LW9521

New password, user 11

32-bit unsigned

Loaded into security system when

LB9061 is set momentarily

LW9522,

LW9523

New password, user 12

32-bit unsigned

Loaded into security system when

LB9061 is set momentarily

To log out a user, use a Set Bit Object to momentarily set bit LB9050.

When Enhanced security mode is selected, each user can be assigned up to twelve access classes (A-L).

Passwords and User Names can be alphanumeric, which are stored in local memory as assigned by the Control

address. One user is reserved as an administrator, which has complete access. The Option List object can be

configured to display the User Names, providing a quick way to select a user to log-in.

In addition, up to 127 more user accounts can be added using the Administrator Tools. See “Chapter 13 –

Security” and “Chapter 14 – Administrator Tools” for more information.

Project password (MTP file): Select this option to set a password in order to prevent unauthorized users from

opening and editing a project. The correct password must be entered in order to open the password-

protected project.