Yokogawa RotaMASS 3-Series User Manual

Page 73

Advertising
background image

IM 01R04B08-00E-E 1st edition February 15, 2012 -00

All Rights Reserved. Copyright © 2012, Rota Yokogawa

<10. GENERAL SPECIFICATIONS>

10-3

Remote field-mount Converter RCCF31, Model, Suffix and Option Code

Model

Suffix Code

Option
Code

Description

Restrictions

RCCF31

Remote field-mount converter to be connected to RCCS3;
when ordered without detector combination option /NC must be selected

Power supply

-A
-D

90 - 264 V AC
24 V DC

Indicator direction

H2
N0

With indicator
Without indicator

Cable conduit connection

M
A

M20 x 1.5, female thread with cable glands
ANSI ½´´ NPT, female thread, only cable gland for detector connection

mandatory with /FF1, /FF2

Hazardous Area Approvals

1)

/KF1
/KF2

/FF1

/FF2

/EF1
/EF2

/UF1
/UF2

ATEX Flame proof converter + Intrinsic safe detector output
ATEX Flame proof converter + Intrinsic safe detector output + Intrinsic safe
outputs
FM approval for USA+Canada, Flame proof converter + Intrinsic safe detector
output + 2 active analog outputs + 2 passive pulse outputs + 1 status input
FM approval for USA+Canada, Flame proof converter + Intrinsic safe detector
output + 1 passive analog output + 1 passive pulse output
IECEx Flame proof converter + Intrinsic safe detector output
IECEx Flame proof converter + Intrinsic safe detector output + Intrinsic safe
outputs
INMETRO Flame proof converter + Intrinsic safe detector output
INMETRO Flame proof converter + Intrinsic safe detector output + Intrinsic safe
outputs

with /HP for gas group IIB
with /HP for gas group IIB

only with cable conduit ´A´; with /HP not for
groups A and B
only with cable conduit ´A´; with /HP not for
groups A and B
with /HP for gas group IIB
with /HP for gas group IIB

with /HP for gas group IIB
with /HP for gas group IIB

Custody Transfer Measurement
acc. OIML R 117-1

/Q01

European MID Approval (fluids other than water) (refer to GS 01R04B07-00E)

GOST

1)

/QR1
/QR2
/QR3

Primary Calibration and Test Confirmation valid in Russia
Primary Calibration and Test Confirmation valid in Kazakhstan
Primary Calibration and Test Confirmation valid in Uzbekistan

see page 9
see page 9
see page 9

Communication

/FB
/MB1

Digital communication Foundation Fieldbus protocol (refer to GS 01R04B05-00E)
Modbus communication protocol for selected parameters and values

not with /FB, /Q01, /KF2, /EF2, /UF2, /FF2, /AP

High Driving Power

/HP

High Driving Power

not for combination with RCCS30 to 34,
recommended for combination with RCCS36 to
39, strongly recommended for combination with
RCCS39/IR, mandatory for combination with
RCCS39/XR

Active Pulse Output

/AP

One active pulse output

not with /KF2, /EF2, /UF2, /NM

NAMUR Switch

/NM

One pulse output acc. EN 60947-5-6 (NAMUR)

not with /AP

Tag Number

/BG

With customer specified tag number on name plate

max. 16 digits

HART Tag Number (Software Tag)

/BT1

With customer specified tag number for HART communication in converter

8 digits for tag, 22 digits for long tag

Gas Measurement

/GA

Gas measurement, special factory adjustments and settings

select affiliated RCCS3 with /GA

Combination with RCCS39/XR

/XR

Special converter adjustment with RCCS39/XR

mandatory for combination with RCCS39/XR

No Combination

/NC

No combination with detector

Customer Presetting

/PS

Presetting sheet with customer data

has to be issued with the order

Epoxy Coating

/X1

Epoxy coating of converter housing

Delivery to Japan

/PJ

For meters which are delivered to Japan with SI-unit preset

Delivery to Korea

/KC

With KC-mark for Korea

Cable glands

/AD2

2 pcs ANSI 1/2“ NPT / G1/2 adapter

only with cable conduit ´A´

Concentration Measurement

2)

/CST
/Cxx

Standard concentration measurement
Advanced concentration measurement, details see table „Advanced Concentration
Measurement Options“

Instruction Manuals

/IEn
/IDn
/IFn

Quantity of instruction manuals in English
Quantity of instruction manuals in German
Quantity of instruction manuals in French

n = 1 to 3 selectable

3)

n = 1 to 3 selectable

3)

n = 1 to 3 selectable

3)

Quick Delivery

/QD

Delivery within 24 hours from factory

not with /KF2, EF2, /FF2, /UF2, /PJ, /AD, /FB, /
GA, /QR1, /QR2, /QR3, /PS, /X1, /MB1

Special order

/Z

Special design must be specification an extra sheet

1)

Select affiliated RCCS3 with the same approval type (e.g. /KFx with /KS1).

2)

For detailed information please see TI 01R04B04-04E-E. Option /K6 of RCCS3 is recommended with concentration measurement.

3)

If no instruction manual is selected, only a DVD with instruction manuals is shipped with the instrument. More than 3 manuals of one language on request.

Advertising