IM 01R04B08-00E-E 1st edition February 15, 2012 -00

All Rights Reserved. Copyright © 2012, Rota Yokogawa

<10. GENERAL SPECIFICATIONS>

10-4

Remote rack-mount Converter RCCR31, Model, Suffix and Option Code

Model

Suffix Code

Option
Code

Description

Restrictions

RCCR31

Remote converter for 19´´ rack mounting to be connected to RCCS3

Power supply

-A
-D

90 - 264 V AC
24 V DC

Hazardous Area Approvals

1)

/KS1
/FS1
/ES1
/US1

ATEX associated apparatus for intrinsic safe detector connection for gas group IIC
FM associated apparatus for intrinsic safe detector output
IECEx associated apparatus for intrinsic safe detector output for gas group IIC
INMETRO associated apparatus for intrinsic safe detector output for gas group IIC

with /HP for gas group IIB
with /HP not for gas groups A and B
with /HP for gas group IIB
with /HP for gas group IIB

GOST

1)

/QR1
/QR2

Primary Calibration and Test Confirmation valid in Russia
Primary Calibration and Test Confirmation valid in Kazakhstan

see page 9
see page 9

High Driving Power

/HP

High Driving Power

not for combination with RCCS30 to 34, recom-
mended for combination with RCCS36 to 39,
strongly recommended for combination with
RCCS39/IR, mandatory for combination with
RCCS39/XR

Active Pulse Output

/AP

One active pulse output

not with /NM

NAMUR Switch

/NM

One pulse output acc. EN 60947-5-6 (NAMUR)

not with /AP

Communication

/MB1

Modbus communication protocol for selected parameters and values

not with /AP

Tag Number

/BG

With customer specified tag number on name plate

max. 16 digits

HART Tag Number (Software Tag)

/BT1

With customer specified tag number for HART communication in converter

8 digits for tag, 22 digits for long tag

Gas Measurement

/GA

Gas measurement, special factory adjustments and settings

select affiliated RCCS3 with /GA

Combination with RCCS39/XR

/XR

Special converter adjustment with RCCS39/XR

mandatory for combination with RCCS39/XR

No Combination

/NC

No combination with detector

Customer Presetting

/PS

Presetting sheet with customer data

has to be issued with the order

Concentration Measurement

2)

/CST
/Cxx

Standard concentration measurement
Advanced concentration measurement, details see table „Advanced Concentration
Measurement Options“

Subrack

/SR2
/SR4

Subrack for 2 converter RCCR31 with mounting
Subrack for 4 converter RCCR31 with mounting

Delivery to Korea

/KC

With KC-mark for Korea

Instruction Manuals

/IEn
/IDn
/IFn

Quantity of instruction manuals in English
Quantity of instruction manuals in German
Quantity of instruction manuals in French

n = 1 to 3 selectable

3)

n = 1 to 3 selectable

3)

n = 1 to 3 selectable

3)

Special order

/Z

Special design must be specification an extra sheet

1)

Select affiliated RCCS3 with the same approval type (e.g. /KS1 with /KS1).

2)

For detailed information please see TI 01R04B04-04E-E. Option /K6 of RCCS3 is recommended with concentration measurement.

3)

If no instruction manual is selected, only a DVD with instruction manuals is shipped with the instrument. More than 3 manuals of one language on request.