1 draining condensate for flushing connection ring, 2 venting gas for flushing connection ring, Venting gas for flushing connection ring -6 – Yokogawa EJX438B User Manual

Page 34: Warning

Advertising
background image

<6. Operation>

6-6

IM 01C27H01-01EN

WARNING

Since the accumulated liquid (or gas) may be

toxic or otherwise harmful, take appropriate care

to avoid contact with the body, or inhalation of

vapors.

6.6.1 Draining Condensate for Flushing

Connection Ring

1) Gradually open the drain screw to drain from

the flushing connection ring.(See figure 6.7.)

2) When the flushing connection ring is completely

drained, close the drain screw.

3) Tighten the drain screw to a torque of 10 N·m

{1 kgf·m}.

F0611.ai

Drain screw

When you loosen the drain screw,

the accumulated liquid(or gas)

will be expelled in the direction of

the arrow.

Figure 6.7

Draining for Flushing Connection Ring

6.6.2 Venting Gas for Flushing Connection

Ring

1) Gradually open the vent screw to vent gas from

the flushing connection ring.(See figure 6.8.)

2) When the flushing connection ring is completely

vented, close the vent screw.

3) Tighten the vent screw to a torque of 10 N·m

F0612.ai

Vent screw

When you loosen the vent screw,

the accumulated liquid(or drain)

will be expelled in the direction

of the arrow.

Figure 6.8

Venting for Flushing Connection Ring