2 model and suffix codes, Model and suffix codes -5, Instruction – Yokogawa EJX438B User Manual

Page 91

Advertising
background image

<10. General Specifications>

10-5

IM 01C27H01-01E

10.2 Model and Suffix Codes

Instruction

The model and suffix codes for EJX118B and EJX438B consist of two parts; a transmitter body section (I) and

a diaphragm seal section (II). This specification sheet introduces these two parts separately. The transmitter

body section is shown in one table, and the diaphragm seal section specifications are listed according to the

process connection style. First select the model and suffix codes of transmitter body section and then continue

on one of the diaphragm seal section.

F03E.ai

I Transmitter body section

II Diaphragm seal section

EJX118B
EJX438B

I. Transmitter body section

T09E.ai

Model

EJX118B

EJX438B

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Diaphragm sealed differential pressure transmitter

Diaphragm sealed Gauge Pressure transmitter

Description

Wireless communication (ISA100.11a protocol)

Output signal

Always S

ASTM-B7 carbon steel

316L SST stainless steel

ASTM grade660 stainless steel

2 to 100 kPa (8 to 400 inH

2

O)

10 to 500 kPa (40 to 200 inH

2

O)

0.035 to 3.5 MPa (5 to 500 psi)

0. 16 to 16 MPa (23 to 2300 psi)

*1

Horizontal piping type and left side high pressure
Cast aluminum alloy with integral antenna

Cast aluminum alloy with detachable antenna (2 dBi)*

5

Cast aluminum alloy without antenna (N connector)*

4

*

5

304 SST 2-inch pipe mounting, flat type (for horizontal piping)

None

Digital indicator

Coverflange bolts and nuts material

Installation
Amplifier housing

Mounting braket


Diaphragm seal section

Integral Indicator

Suffix codes

-

L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

J . . . . . . . . . . . . . . . . . . . . . .

G . . . . . . . . . . . . . . . . . . . . . .

C . . . . . . . . . . . . . . . . . . . . . .

D . . . . . . . . . . .

-9 . . . . . . . . . . . . . . . . . . .

S . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Always C

C . . . . . . . . . . . . . . . . . . . . . . . . .

EJX118B

EJX438B

Continued on diaphragm seal section (II)

7 . . . . . . . . . . . . . . . . .

8 . . . . . . . . . . . . . . . . .

9 . . . . . . . . . . . . . . . . .

B . . . . . . . .

N . . . . . . . .

Measurement span

(capsule)

M

*2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H

*2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

A

*3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

B

*3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

No electrical connection, battery-powered type (battery case only; battery cells

not included)

J . . . . . . . . . . . . . .

Electrical connection

The “►” marks indicate the most typical selection for each specification.

*1:

When specified process connection style code E, maximum range and span are 7 MPa (1000 psi.)

*2:

Applicable for EJX118B

*3:

Applicable for EJX438B

*4:

Order the antenna separately from accessary option.

*5:

Remote antenna cables can be attached. Order separately from accessary option.