IM 04L41B01-62EN

1

2

3

4

5

Index

Detailed Information for

Attributes of Screens and Components

3.28 Attributes of Trend Components

The following limitations exist for attribute setting for trend components.
• [Visible] can only be set when [Depend ID] is set to [None].
• The time/div font cannot be set when Time/div display is [Off].
• The message mark size cannot be set when message mark display is [Off].
• 2nd span upper limit and 2nd span lower limit cannot be set when 2nd span is [Off].
• 2nd span upper limit and 2nd span lower limit cannot be switched against each other.
• When the synchro target is [Switch], alarm level setting is not possible.
• If the MultiBatch function is not enabled, the [Batch group no.] cannot be set.
• When [Time Grid Display] is [Off], the time grid for trend components is not displayed.
• When [Scale Grid Display] is [Off], the scale grid for trend components is not

displayed.

• When the [Time Grid Display] and [Scale Grid Display] are [Off], the background fill

color is applied without displaying the frame.

• When the [Time Grid Display] is [Off], the [Time display] is [Off] and cannot be set.
• When the [Time Grid Display] is [Off], the [Time font] and [Time interval] cannot be set.
• When [Time display] is [Off], the [Time interval] and [Time font] cannot be set.