Index – Yokogawa Button Operated DX2000 User Manual

Page 38

Advertising
background image

2-25

IM 04L41B01-62EN

1

2

3

4

5

Index

Creating a Monitor Screen with DAQStudio

Status display components (can only be set with a Version 4.01 screen and a

Version 4.11 screen)

Group name

This component displays the group name corresponding to the specified group number.
You can create this group name component when you want to display components from
multiple groups, or if setting the status area to No display eliminates the group name.

Group name

Component area

If you set Change group to On in the attribute

settings, the group name changes when you press

the left/right arrow keys on the execution panel.

Vertical display

System icon

Creates a system icon for display in the status area. You can create icons that display
only the items you wish in the screen, for use when not displaying the status area.

Component frame

The size of the icon

component frame is set

under Icon size in the

attribute settings.

Memory sample

Alarm

CF card

Math

Key Lock

Email

Status

Key lock & email

User Lock

UserLock & status

Memory bar

This component appears in the status area and shows the progress of memory sampling.
The width of the memory bar component frame represents the file save interval (display
data) or data length (event data), and shows the remaining time for memory sampling.

File save interval (for display data),

or data length (for event data)

Background

Bar

Remaining memory sample time

For event data, the status is displayed as a text label.

This is not displayed on DX recorders with the /AS1 option.

Time label

This component displays the current date and time.
You can create this Date and time component if setting the status area to No display
eliminates the date and time.

Time

Background

Date

Vertical display

2.8 Components Explanation and Creation Examples

Advertising
This manual is related to the following products: