5.3 Changing the Screen Version

When you switch the screen version, the screen construction data is converted to the
new version.

When switching from Version 3 to Version 4.01 or Version 4.11

Version 3 component attributes remain the same.

Component attributes that became available for setting in Version 4.01 or Version 4.11
are set to their defaults.

[2nd span Lower] and [2nd span Upper] settings of trend and scale components can
now be set up to 1 decimal place.

When switching from Version 4.01 to Version 4.11

Version 4.01 component attributes remain the same.

Component attributes that became available for setting in Version 4.11 are set to their
defaults.

When switching from Version 4.01 or Version 4.11 to Version 3

Components not supported in Version 3 are deleted.

The [Depend ID]’s of components dependent on other components not supported in
Version 3 are set to [None]. - Attributes of components not supported in Version 3 are
deleted. The [Vertical display] of components whose attributes are deleted (Labels,
Tag no., Tag comment, Units, SpanL, and SpanU) is changed to [Off] (horizontal
display).

Attributes of components not supported in Version 3 are deleted. The method of
plotting is changed for components whose attributes are deleted (trend and scale).

For the trend component’s [2nd span Lower] and [2nd span Upper] settings, the
number of decimal places is changed to 0, and the number after the decimal point is
rounded.

For the scale component’s [2nd span Lower] and [2nd span Upper] settings, the
number of decimal places is changed to 0, and the number after the decimal point is
rounded.

If not displaying the status area in a Version 4.01 screen or Version 4.11 screen, it is
displayed. Components in the status area are repositioned.

When switching the status area from [No display] to [Display], components overlapping

the status area move into the screen display area. Also, if the height of a component
exceeds the maximum value for the screen construction area, the height is changed
to the maximum value.

When switching from Version 4.11 to Version 4.01

Components not supported in Version 4.01 are deleted.

Attributes of components not supported in Version 4.01 are deleted.

・ The method of plotting is changed for components whose attributes are deleted.

Component differences by screen version

Component

Version 3 screen

Version 4.01 screen
Version 4.11 screen

System icon

New

Group name

New

Batch group number

New

Batch name

New

Time label

New

Memory bar

New

Modbus In

New

5-5

IM 04L41B01-62EN

Messages and Handling Methods