3.17 Attributes of Batch Name Components

(Can only be set with a Version 4.01 screen and a Version 4.11 screen)

The following restrictions apply to the attribute settings of batch name components.
• [Visible] can only be set when [Depend ID] is set to [None].
• When the Batch function is Off in the settings file, no attributes other than X, Y, Width,

and Height can be set.

• If the Batch function is On in the settings file, [Batch group no.] cannot be set.
• The MultiBatch number specified in the settings file is the maximum value for [Batch

group no.].

List of Settings

Refer to Section 3.3 for attributes without explanations in the list of settings.

Attribute

Set value/choice
(Underlined items are initial

set values)

Description, conditions

X

DX1000: 0 to 318
DX2000: 0 to 638

This is the X-coordinate of the left side of the component.
X = 0 for X < 0
X = (Max.

width

*1

– Width) for (X + Width) > Max. width

*1

Y

DX1000: 24(0) to 238
DX2000: 40(0) to 478
( ) = Status area set to No

display

This is the Y-coordinate of the right side of the component.
When Y < min. Y

*2

, Y = min. Y

*2

When (Y + size) > (min. Y

*2

+ max. height

*3

), Y = (min. Y

*2

+ max.

height

*3

- size

*1

DX1000 max. width = 320, DX2000 max. width = 640

*2

DX1000 min. Y = 24(0), DX2000 min. Y = 40(0), ( ) = Status area set to No display

*3

DX1000 max. height = 216(240), DX2000 max. height = 440(80), ( ) = Status area set to No display