16 attributes of batch group number components, 16 attributes of batch group number components -32 – Yokogawa Button Operated DX2000 User Manual

Page 93

Advertising
background image

3-32

IM 04L41B01-62EN

3.16 Attributes of Batch Group Number

Components

(Can only be set with a Version 4.01 screen and a Version 4.11 screen)

The following restrictions apply to the attribute settings of batch group number
components.
• [Visible] can only be set when [Depend ID] is set to [None].
• The MultiBatch number specified in the settings file is the maximum value for [Batch

group no.].

• If the Batch function is Off or On in the settings file, a batch group number component

cannot be created. For existing batch group number components, no attributes other
than X, Y, Width, and Height can be set.

List of Settings

Refer to Section 3.3 for attributes without explanations in the list of settings.

Attribute

Set value/choice
(Underlined items are initial

set values)

Description, conditions

X

DX1000: 0 to 318
DX2000: 0 to 638

This is the X-coordinate of the left side of the component.
X = 0 for X < 0
X = (Max.

width

*1

– Width) for (X + Width) > Max. width

*1

Y

DX1000: 24(0) to 238
DX2000: 40(0) to 478
( ) = Status area set to No

display

This is the Y-coordinate of the right side of the component.
When Y < min. Y

*2

, Y = min. Y

*2

When (Y + size) > (min. Y

*2

+ max. height

*3

), Y = (min. Y

*2

+ max.

height

*3

- size)

*1

DX1000 max. width = 320, DX2000 max. width = 640

*2

DX1000 min. Y = 24(0), DX2000 min. Y = 40(0), ( ) = Status area set to No display

*3

DX1000 max. height = 216(240), DX2000 max. height = 440(80), ( ) = Status area set to No display

Advertising