Processing alarm statuses, Processing alarm statuses -6, Processng alarm statuses – Yokogawa DAQWORX User Manual

Page 37

Advertising
background image

3-6

IM WX1-07E

Processng Alarm Statuses

Each model’s alarm types are changed as follows before being sent to DAQLOGGER

and Remote Monitor.

Alarm Type on Devce Sde

Alarm Type after Change
PV

SP

OUT, HOUT, COUT

PV high limit

PV high limit [H]

PV low limit

PV low limit [L]

Deviation high limit

Deviation high limit [DH]

Deviation how limit

Deviation low limit [DL]

De-energized on deviation high limit
alarm

Deviation high limit [DH]

De-energized on deviation low limit
alarm

Deviation low limit [DL]

Deviation high and low limit

Other [ETC]

Deviation within high and low limit

Other [ETC]

De-energized on PV high limit

PV high limit [H]

De-energized on PV low limit

PV low limit [L]

PV high limit

(with idle mode)

PV high limit [H]

PV low limit

(with idle mode)

PV low limit [L]

Deviation high limit

(with idle mode)

Deviation high limit [DH]

Deviation low limit (with idle mode)

Deviation low limit [DL]

De-energize on deviation high limit
alarm (with idle mode)

Deviation high limit [DH]

De-energize on deviation low limit alarm
(with idle mode)

Deviation low limit [DL]

Deviation high and low limit

(with idle mode)

Other [ETC]

Deviation within high and low limit

(with idle mode)

Other [ETC]

De-energized on PV high limit

(with idle mode)

PV high limit [H]

De-energized on PV low limit

(with idle mode)

PV low limit [L]

Timer function upward (hour/minute)

Other [ETC]

Timer function downward (hour/minute)

Other [ETC]

Timer function upward (minute/second)

Other [ETC]

Timer function downward

(minute/second)

Other [ETC]

Sensor grounding alarm

Other [ETC]

Fault diagnosis output

Other [ETC]

FAIL output

Other [ETC]

Timer function

Other [ETC]

De-energized on timer function

Other [ETC]

Heater burnout alarm 1

Other [ETC]

Heater burnout alarm 2

Other [ETC]

Heater burnout

Other [ETC]

SP high limit

Other [ETC]

SP high limit [H]

SP low limit

Other [ETC]

SP low limit [L]

Output high limit

Other [ETC]

Output high limit [H]

Output low limit

Other [ETC]

Output low limit [L]

PV velocity alarm

Other [ETC]

PV velocity alarm passive

Other [ETC]

Self-diagnostic alarm

Other [ETC]

Self-diagnostic alarm passive

Other [ETC]

FAIL passive

Other [ETC]

Deviation high limit for target setpoint

Other [ETC]

Deviation high limit [DH]

Deviation low limit for target setpoint

Other [ETC]

Deviation low limit [DL]

(cont. on next page)

3.3 Detals on Functons